IFCPC
IFCPC Colposcopy Guidelines and 2011 Terminology
Official terminology context for standardized colposcopic assessment.
Open reference
IFCPC protocol-guided digital colposcopy
Follow the IFCPC protocol, record images and measurements and prepare the colposcopy report.
Product in use
Review images, record findings and prepare the report.
Clean visual reference before contrast. Cervix documented with image and position.
Acetowhite findings mapped with image, location, and measurement in mm.
Schiller test with contextual record. Iodine-negative areas marked on the cervix map.
Final record with images, measurements, map, and structured report ready for review.
Quick product demo
A concise walkthrough of voice-guided flow, IFCPC sequence, and structured report in the same clinical session.
Opens in an overlay without taking the visitor away from the page.
Open demo pageUse the dedicated demo page when you want to share the video with a stable, indexable link.
Measurements recorded in millimeters during the session and available in the report.
Visible-light colposcopy gains a clearer path to centralized archives, PACS-connected workflows, and institutional interoperability.
Eligible cases can support anonymized benchmark, multicenter science, and physician-led collaboration under explicit governance.
Capability details
Examination protocol, images, measurements and documentation.
IFCPC Protocol
Baseline, acetic acid, Lugol, and findings guided by IFCPC Protocols. The software ensures no step is skipped.
Measurements in mm
The physician measures findings in millimeters directly in the interface. Measurements accompany the report for future comparison.
DICOM and PACS
RMColpo helps organize visible-light exams as structured clinical records, with a more professional path to DICOM, PACS-connected archives, and hospital-grade integration when needed.
Live streaming
Share the exam live with a colleague for immediate discussion. Ideal for complex cases, supervision, and teaching.
Study Center
When physicians and institutions opt into a Study Center, eligible cases can be organized for anonymized scientific use under the governance of the medical leaders responsible for the center.
International rollout
RMColpo keeps the same guided workflow while supporting international deployment, localized interfaces, and multicenter collaboration across services that need a shared scientific and operational baseline.
These focused pages answer the questions that usually appear after the first conversation, without sending the visitor back to the homepage.
RMColpo
Short product overview with the guided flow, IFCPC sequence, and structured report.
Open the demo pageRMColpo
A practical buying guide to compare guided workflow, structured reports, collaboration, and clinic rollout fit.
Review the evaluation criteriaRMColpo
See how baseline, acetic acid, Lugol, and findings stay aligned with the correct exam phase.
Understand the protocol flowRMColpo
Understand how RMColpo works as a colposcopy reporting system, keeping image, findings, and measurements connected in the same session.
See the reporting-system logicRMColpo
See how live sharing supports supervision, case discussion, and remote collaboration.
See the second-opinion flowRMColpo
Governance, team standardization, and how the platform supports multi-physician operation.
See the clinic rollout angleTell us which exams you perform, your expected volume and team needs. Contact us for pricing.
Who it's for
Choose the option for your practice.

For specialists
IFCPC-guided session with contextual images and structured report at the end — no rework.

For clinics and hospitals
Every physician follows the same IFCPC protocol. Structured output for quality review and multi-unit governance.

For OEM and distributors
Ship IFCPC protocols, structured reporting, and live streaming inside the device — real clinical value from day one.
Research, governance, and teaching
Reuse documented cases with consent and appropriate governance.
Structured cases accumulate over time in a format that supports retrospective analysis, cohort views, and follow-up comparison.
Clinical images can be organized by finding, phase, and protocol, creating a reusable visual library for teaching, review, and scientific discussion.
Eligible scientific material is prepared with anonymization and governed access, under the rules defined by the physicians and institutions that lead the Study Center.
Structured records can support external analysis, publications, and institutional workflows that need a cleaner path to interoperable archives and governed reuse.
Participating centers can contribute under the same report structure, protocol taxonomy, and comparison baseline, making broader statistics and collaborative studies more consistent.
Documented sessions remain usable for case review, consensus discussion, supervision, and training new colposcopists.
Scientific network
RMColpo keeps structured exam data ready for research, and the Study Center turns that foundation into physician-led governance, anonymized multicenter collaboration, benchmark, and broader scientific analysis across participating services.
Explore the Study CenterYes. RMColpo is not only an image capture surface. It works as a colposcopy reporting system by keeping protocol steps, findings, measurements, and structured output connected inside the same exam workflow.
Tell us your exams, volume and required features. Our team will confirm the scope and pricing; no approved ReportMed prices are published here.
Discuss the number of physicians, access permissions, review responsibilities and implementation needs with our team.
Inform your expected volume when requesting a proposal. Evaluate the reporting workflow and required features in the demonstration.
OEM projects run through a consultative path. We evaluate embedded protocol workflow, white-label or channel model, support scope, and deployment format together with your team.
RMColpo helps organize visible-light colposcopy as a structured clinical record, with a clearer path to DICOM, PACS-connected archives, and hospital-grade integration when institutional continuity is required.
Yes. When physicians or institutions opt into a Study Center, eligible cases can be cataloged for scientific use under physician-led governance, with anonymization before broader sharing and multicenter collaboration.
Yes. The same structured workflow can be deployed across countries and services with localized interfaces, consistent documentation logic, and a shared scientific baseline for international collaboration.
Yes. Public pricing follows an annual agreement. Final commercial terms are aligned during the guided evaluation according to market, workflow, and rollout scope.
No. The software organizes the exam flow by IFCPC Protocols and generates the structured report. Interpretation and decision-making remain with the specialist.
Yes. The session ends with a structured report containing images, findings, mm measurements, and cervix map — ready for review and signature.
Yes. Streaming occurs through a private encrypted channel, accessible only by invitation from the responsible physician.
See RMColpo and ask your questions.